Relay Emergency
Brake System

Previous Page Contents Next Page

When pressure in the supply line exceeds 80 psi the 110257 opens allowing pressurized air to enter the reservoir. The primary purpose of the 110257 is to keep the supply line at 70 psi or higher in case of a failure in the brake system. The system will continue to fill with pressure until it reaches the tractor’s maximum supply capability.