Light |
Blink Code |
Cause |
Location |
Checks |
 |
3 |
Sensor C |
Sensor or
sensor cable. Follow cable from port labeled with port number to the wheel end. |
Check cabling
for short or no circuit, hub for excessive runout, exciter ring for damage, and
sensor gap. |
 |
4 |
Sensor D |
 |
5 |
Sensor E |
 |
6 |
Sensor F |
 |
7 |
External Modulator |
External modulator and/or
cable |
Check the cable for
connection and continuity. Verify valve function. |
 |
9 |
Internal Modulator |
Internal Modulator Failure H2 |
Verify proper
installation. If code continues, contact Meritor WABCO for assistance. |
 |
10 |
Internal Modulator Failure H1 |
 |
11 |
No Speed Failure |
 |
12 |
Pnuematic Supply |
Control Pressure Failure |
|
 |
13 |
Pnuematic Supply |
Supply Pressure Failure |
|
 |
14 |
Power Supply |
Power cabling and
connectors |
Verify proper electrical
installation. Check power supply. |
 |
15 |
ECU Failure |
ECU Internal
Failure |
Will appear on systems that have not completed end of the line service. Verify proper
installation. If code continues, contact Meritor WABCO for assistance. |
 |
16 |
SAE J1708 Failure |
Contact
Meritor WABCO for assistance. |
 |
17 |
SAE J2497 Failure |
 |
18 |
Generic IO Failure |
Cabling |
Verify proper electrical
installation. Check power supply. |
 |
19 |
ECU |
Load Sensing Failure |
|
 |
20 |
ECU |
Roll Stability Failure |
|